Overview
MTL4517 – MTL5517 SWITCH/ PROXIMITY DETECTOR INTERFACE
The British MTL Safety Barrier – MTL4517 module controls 2 safety zone loads through a proximity switch or switch in the danger zone. A line fault is signaled via a separate relay while indicating at the top of the module. The switch on the UK MTL Safety Barrier-MTL4517 module is used to select the inverting position and enable line fault detection.
The MTL5500 series is a versatile product at the application level and is simple to operate. It is manufactured with technology and has been well-verified. These comparative attributes are derived from advances in MTL’s expertise in the design and manufacture of intrinsically safe optoisolators and the application of MTL’s innovative technologies to achieve the required separation and isolation circuits. This MTL5500 (DIN-rail mount) and MTL4500 (backplane mount) are recommended to share a common design, differing only in mechanical mounting and connection methods.
MTL4517 – MTL5517 Related Products
- MTL4501-SR Fail-safe solid-state output + line fault detection (LFD) alarm
- MTL4504 Switch/proximity switch input, inverting + line fault detection (LFD)
- MTL4510 Switch/proximity switch input, solid-state output
- MTL4510B Multi-function switch/proximity switch input, solid-state output
- MTL4511 Switch/proximity switch input, C/O relay output
- MTL4513 Switch/proximity switch input, solid state output
- MTL4514 Switch/proximity switch input, relay + line fault detection (LFD)
- MTL4514B Switch/proximity switch input, relay + line fault detection (LFD)
- MTL4516 Switch/proximity switch input, relay + line fault detection (LFD) output
- MTL4516C Switch/proximity switch input, C/O relay + line fault detection (LFD) output
- MTL4517 Switch/proximity switch input, relay + line fault detection (LFD) output
- MTL4521 Loop-powered solenoid valve actuated isolation barrier, IIC
- MTL4521L Loop-powered solenoid valve actuated isolation barrier, IIC
- MTL4523 Solenoid operated isolator with line fault detection (LFD), IIC
- MTL4523L Loop-powered solenoid with line fault detection (LFD) actuated isolation barrier, IIC
- MTL4523R Solenoid valve with inverting line fault detection (LFD) actuated isolation barrier, IIC
- MTL4523V Solenoid operated isolator with line fault detection (LFD), IIC
- MTL4524 Switch input, solenoid valve actuates the isolation barrier
- MTL4524S Switch input, solenoid valve driven isolation barrier, 24V override
- MTL4525 Switch input, solenoid valve actuated isolation barrier, low power
- MTL4526 Switching outputs, relays
- MTL4531 Vibration probe isolation barrier
- MTL4532 Pulse isolator, digital or analog output
- MTL4533 Vibration probe safety barrier
- MTL4541 2/3-wire transmitter isolation barrier
- MTL4541A Transmitter repeater, active input
- MTL4541AS Transmitter repeater, active input, passive output
- MTL4541S 2/3-wire transmitter isolation barrier, passive output
- MTL4544 2/3-wire transmitter isolation barrier
- MTL4544A Transmitter repeater, active input
- MTL4544AS Transmitter repeater, active input, passive output
- MTL4544S 2/3-wire transmitter isolation barrier, passive output
- MTL4544D 2/3-wire transmitter isolation barrier, 1 in and 2 out
- MTL4546 4-20mA intelligent isolated drive + line fault detection (LFD)
- MTL4546Y 4-20mA Intelligent Isolation Drive + OC Line Fault Detection (LFD)
- MTL4549 4-20mA intelligent isolated drive + line fault detection (LFD)
- MTL4549Y 4-20mA Intelligent Isolation Drive + OC Line Fault Detection (LFD)
SPECIFICATION
Number of channels: Two
Location of switch:
Zone 0, IIC, T6 hazardous area,
Div.1, Group A, hazardous location
Location of the proximity detector:
Zone 0, IIC, T4–6 hazardous area, if suitably certified
Div.1, Group A, hazardous location
Hazardous-area inputs:
Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
The voltage applied to the sensor: 7 to 9V DC from 1 kΩ ±10%
Input/output characteristics:
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected):
User selectable by switches on the side of the module.
Line faults are indicated by the LED for each channel.
The line fault relay is energized and the channel output relay is de-energized if an input line fault detected
The open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω
Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with the switch
Safe-area output:
Channel: Two single-pole relays with normally open contacts
LFD: Single pole relay with changeover contact (MTL4517)
Single pole relay with normally open contact (MTL5517
Note: reactive loads must be adequately suppressed
China Air Compressors Trade Service company helps you save time and money when purchasing genuine original Honeywell parts from China. Our company also provide genuine parts for world reputable compressors brands such as Atlas Copco, Ingersoll Rand, and Sullair compressors, vacuum pumps, Epiroc drilling rigs, etc.
Our compressors, spare parts, and tools customers are from around the globe, and here are just a few of them: Armenia, Azerbaijan, Bahrain, Bangladesh, Brunei, Cambodia, Cyprus, South Korea, Indonesia, Iran, Iraq, Japan, Jordan, Kazakhstan, Kuwait, Kyrgyzstan, Laos, Lebanon, Malaysia, Mongolia, Myanmar, Nepal, Oman, Pakistan, Philippines, Qatar, South Korea, Saudi Arabia, Singapore, Syria, Tajikistan, Thailand, Turkey, Turkmenistan, United Arab Emirates, Uzbekistan, Viet Nam, Australia, New Zealand, Papua New Guiana, and African countries such as Nigeria, Kenya, Zambia, South Africa, etc, South American Countries: Brazil, Colombia, Peru, Chile, Argentina, etc, and the USA, Canada, Spain, France, Italy, etc few European countries.